CHLORIDIOX CP SERIES - Onsite Chlorine Dioxide Generators

The IEC chlorine dioxide generator offers a simple and effective way of generating a low strength chlorine dioxide solution.clo2

 

  • Safe, on-demand production of chlorine dioxide
  • Simple, reliable operation. Safety interlock as mandatory
  • Fully automatic or manual operation
  • Low maintenance
  • metering pumps for precise metering
  • Calibration columns provide a simple, economical method for settling pump flow rates
  • As basic chemicals for the generation of chlorine dioxide unit uses hydrochloric acid (32% Hcl) and sodium chlorite (25% NaClO2). Both reagents are metered directly from commercial carboys or intermediate storage tanks into the reaction tower where a chlorine dioxide solution is produced.

The CHLORIDIOX Advantage

  • Operates simply, reliably and safely
  • Retrofits easily into existing chlorination facilities
  • Minimizes materials handling and maintenance
  • Eliminates chlorine gas & concentrated hypochlorite solutions
  • Produces stable, low concentration chlorine dioxide
  • Modular construction for adding generators adjacent

The Process

Acid-chlorine is the simplest and easiest to operate generation chemistry. This is a consequence of the use of only two feeds and its simple reaction chemistry. Instead of having to balance the amounts of sodium chlorite and hydrochloric acid, one merely has to provide sufficient hydrochloric acid. The theoretical conversion of sodium chlorite to chlorine dioxide is only 80%.

System components

1
Feed Line Naclo2
2
Feed Line Hcl
3 & 3a
Flow meter
4
Reactor
5
Mixer
6
Metering Pump
7
Metering Pump
8
Solenoid valve
9 & 9a
Flow control valve
10
Pressure gauge
11 & 11a
Flow switch
12 to 19
Ball valve
20 & 21
Needle valve
22 & 23
Check valve
24
Control panel
25 & 26
Calibration column

System Features

  • Equally suitable for continuous and intermittent operation
  • High stability of the generated chlorine dioxide solution lasting over several days
  • Safe automatic restart after mains failure
  • Integrated dosing pump for chlorine dioxide

SPECIFICATIONS

Model

CP 1.35

CP 2

CP 4

CP 10

CP 20

CP 30

CP 40

CP 50

Cap ClO2

1.35kg/h

2kg/h

4kg/h

10kg/h

20kg/h

30kg/h

40kg/h

50kg/h

Feed water LPH

320

473

947

2368

4736

7104

9472

11840

Naclo2 25% LPH

10.8

16

32

80

160

240

320

400

Hcl 32% LPH

6.7

11

21

52

104

156

208

260

Outlet ClO2 Solution flow LPH

337.5

500

1000

2500

5000

7500

10000

12500

Power

Max 3.50 amps

Max 1kw

Max Back process
@ Dosing kg/cm2

4

7

4

Feed water for req
for Max back process kg/ cm2

6

9

6

Skid Dimensions

Length – In  (mm) L

1000

1500

2000

Width –   In  (mm) W

350

400

500

Height –  In  (mm) H

1500

2000

2400

Max wt kg

 

 

 

* For gravity feed dosing min feed water process is 4kg/cm2

CHLORINE DIOXIDE

Chlorine dioxide is a reactive oxidizing gas that is readily soluble in water. Even dilute solutions (10 ppm) of chlorine dioxide have a characteristic yellow color. The maximum chlorine dioxide concentration typically 4000 ppm. This is to minimize the concentration of chlorine dioxide gas in equilibrium with the solution.

GENERATOR AUTOMATION

Chlorine dioxide generators are automated to provide modulation of chlorine dioxide feed rates based upon changes in flow (flow paced control) and chlorine dioxide demand of the water being treated ( residual control). Theoretically, the chlorine dioxide feed rate may be varied by either modulating the precursor chemical feed rates to the generator or by turning the generator on and off.

    Copyright IEC Fabchem Limited. All rights reserved.